COOL BLASTER® HIGH PRESSURE COOLANT SYSTEMS
Direct high-pressure coolant increases tool life and improves finishes
Exceptional tool for performing deep hole operations such as gun-drilling and boring. Properly applied, high-pressure coolant is an effective solution for all chip control problems.
Cycle time for drilling can be reduced 40–70% with direct high-pressure coolant. The material is less likely to work harder, making drilling easier and in many cases eliminating the need for peck drilling cycles!
High-speed Drilling Operations
Chip Control For Turning And Grooving Improved Surface Finish
Increased Tool Life
Reduced Cycle Time
Greater Throughput
5 Line System
Model CB105V
Coolant is continuously filtered through 5 micron filter
Independent feed pump improves filter bag life
5 high pressure coolant lines
Washable air inlet filter
Space saving vertical design
5 & 10 Line Systems with Heat Exchanger
Model CB510 Available in Horizontal & Vertical Designs:
Coolant moves through 5 micron filter and heat exchanger providing filtration and heat removal even when the high pressure system is not in operation reducing operating temperature of the coolant.
Features:
Independent feed pump standard
2,000 CFM heat exchange system standard
Vertical or horizontal design
Available in 5 and 10 line systems
Specifications:
2,000 PSI, 6.5 GPM
7.5 HP
5 micron filtration
Heat exchange system
PLC control integration
Electrical interface harness
Installation kit (HP hoses, fittings, manifold blocks for coolant distribution)
Diagnostic indicator lights
Restricted filter automatic shut off
Voltage: 200/230V 40.0 full load amps (optional 440/480V 30.0 full load amps)
Dual Filter High Pressure Coolant System
Model CB610V 10 Line System with Heat Exchanger:
The CB610 dual filter system is designed to automatically change-over to the secondary filter when the primary filter becomes clogged. The filter change-over will not stop production, therefore unattended or third shift operations can continue without disruption.
Features:
No loss of production to change clogged filter
Automatic change over from clogged filter to clean filter
System removes excess heat from coolant during operation
Independent feed pump improves filter bag life
Air purge system automatically removes coolant from clogged filter canister
Washable air inlet filter provides clean air flow for heat exhange system
Space saving vertical design: 19.5” x 51.4” x 43.4”
Specifications:
2,000 PSI, 6.5 GPM
7.5 HP
5 micron filtration
Heat exchange system
PLC control integration
Electrical interface harness
10 high pressure coolant lines
Installation kit (HP hoses, fittings, manifold blocks for coolant distribution)
Diagnostic indicator lights
Voltage: 200/230V 40.0 full load amps (optional 440/480V 30.0 full load amps)